C.
IR
and
GC
Product
Analysis
Infrared Analysis
Infrared spectra were recorded on a Nicolet Impact 41 0 spectrometer equipped with an
InspectIR microscope using a random sampling of single beads
Figures
16
and
17 are
representative spectra of the PS-DES resin and the corresponding resin-bound ether.
Gas Chromatography
Analysis
Gas chromatography was performed on a Hewlett-Packard 6890 GC with automatic
sampler,
split/splitless injector, thermal conductivity detector, and
a
HP-5
phenylmethylsilicone capillary column (30 m
x
0.32 mm
x
0.25 pm).
Figure
18 through
22
are representative chromatograms of the alcohol products.
Temperature profile: initial temp 175OC, hold
3
min, ramp at 20°C/min
to
30O0C, hold
1
min.
Flow rate:
1.5
mllmin.
Injection size:
3
pL.
Retention times of alcohols and carbonyl products obtained from RVs
1-5
(1-(2-
methoxybenzoy1)-2-pyrrolidinemethanol,
1 -naphthaleneethanol, 2,2-diphenylethanol,
epiandrosterone, 4-biphenylmethanol) were: 6.6,4.1,4.5, 8.9,4.9 min., respectively.